WOHLER SM 500 (SUSPENDED PARTICULATE ANALYZER)

Code: 8949

WOHLER SM 500  (SUSPENDED PARTICULATE ANALYZER)

The world’s first multi-functional analyzer for onsite mass concentration measurements of total suspended particulate matter in flue gas, O2 and CO, draft and stack temperature.

Description

The Wöhler SM 500 analyzer will give you immediate readings.
Laboratory based analysis becomes superfluous.
The all new TUV certified technology allows onsite mass concentration measurements on all solid fuel fired appliances. Mass concentration limits as low as 20 mg/m³ (maximum emission rate of wood stoves in Germany) can accurately be verified.

The simple user interface and the technician-friendly 4 button key pad make your work fast and accurate. The brilliant full color LED display shows the mass concentration and all combustion values on one screen. After the sampling process the instrument automatically calculates all results to allow compliance testing for solid fuels.

Scope of delivery:

  • 1 x Wöhler SM 500 Suspended Particulate Analyzer
  • 1 x Auxiliary Probe Heater for Wöhler SM 500
  • 1 x Probe 450 mm, straight for Wöhler SM 500
  • 1 x PC-Software Wöhler SM 500 EN
  • 1 x Silica gel70 gr, for SM 500 for approx. 10 measurements

  • 1 year warranty (Excluding consumables such as filters)
TECHNICAL DATA
Suspended Particulate Matter concentration / Filter load (mStF) in 15 min
  • Reading : Filter load in mg
  • Sensor technology : real time digital mass scale
  • Range : 0,0 to 45,0 mg (equals 0,0 mg/m3 to 1.000,0 mg/m3 in flue gas)
  • Accuracy : ± 0.3 mg
Sample rate (VolS)
  • Reading : standard litre per minute (slpm)
  • Sensor technology: : Differential pressure
  • Range : 4,5 Li.N./min and 3,0 Li.N./min
  • Accuracy : ± 5 %
Oxygen (O2) concentration in flue gas
  • Reading : % of flue gas volume (dry conditions)
  • Sensor technology : electrochemical sensor
  • Range : 0.0 to 21,0 %
  • Accuracy : ± 0.3 % according to VDI 4206 - 1
Carbone monoxide (COV) in flue gas
  • Reading : ppm of flue gas volume (dry conditions)
  • Sensor technology : electrochemical sensor
  • Range : 0 to 100,000 ppm, resolution 1 ppm (< 32,000 ppm), rest 10 ppm
  • Accuracy : ± 100 ppm (< 1.000 ppm), rest 10 % of reading according to VDI 4206 - 1
Draft (PD)
  • Reading : Pascal
  • Sensor technology : Semiconductor
  • Range : 0.00 to ± 110.00 hPa, resolution 1 Pa
  • Accuracy : 3 Pa (<100 Pa), 3 % of reading
Flue gas temperature (TA)
  • Reading : °C
  • Sensor technology : Thermocouple (NiCr-Ni)
  • Range : -20.0 °C to 800.0 °C, resolution 0.1 °C
  • Accuracy : according to VDI 4206 Blatt 1
Calculated Values
  • mSt : Total suspended particulate matter mass concentration in flue gas refered to the adjustable oxygen reference value in mg/m3
  • Vol : Sample volume in SL
  • O2 : O2 concentration in % given as 15 min average value
  • COv : CO concentration in ppm given as 15 min average value
  • COn : CO air free concentration in ppm referred to the adjustable oxygen reference value
  • Power Supply : 230 V, 50 Hz, max. 1,200 W
  • Storage temperature : -20 °C to +50 °C
  • Work temperature : +5 °C to 40 °C
  • Weight : approx. 15 kg
  • Dimensions : 480 x 240 x 550 mm