WOHLER DC 410 Flow (STANDARD SET)

Code: 9286

WOHLER DC 410 Flow For measurement of pressure, air flow, temperature and relative humidity, Range : ± 100 hPa , -20 °C to 60 °C

Description

WOHLER DC 410 Flow (STANDARD SET)
Wöhler from Germany

  • One instrument for measurement of pressure, air flow, temperature and relative humidity
  • Is tested to comply with standards for ‘Ventilation for buildings – test procedures & measuring methods for handing over installed ventilation and air conditioning systems’

Feature

  • MULTI-FUNCTIONAL
    For measurement of pressure, air flow, temperature and relative humidity

     

  • HIGHLY ACCURATE
    With “no drift technology”

     

  • TECHNICIAN FRIENDLY
    One hand operation with 4 button keypad

     

  • TESTED TO COMPLY WITH STANDARDS
    Ventilation for buildings – test procedures & measuring methods for handing over installed ventilation and air conditioning systems

Scope of delivery:

  • 1 x Wöhler DC 410 Flow US-Version
  • 1 x Plastic Case Wöhler DC 4xx
  • 2 x Wöhler DC 410FLOW Flexible Capillary 3 m

รับประกัน 1 ปี (ไม่รวม battery)

  • รับประกัน 1 ปี (ไม่รวม battery)
TECHNICAL DATA
Differential Pressure
  • Range : ± 100 hPa
  • Accuracy : < 3 % of the reading, if the value is < ± 5 Pa, better than ± 0,15 Pa
  • Resolution : 0.01 Pa within the range ± 110 Pa, 0.1 Pa within the range ± 1,000 Pa, otherwise 1 Pa
Air speed
  • Range : 0.3 m/s to 120 m/s
  • Resolution : 0.01 m/s
  • Continuous density correction: automatic, with temperature signal
Temperature (internal sensor)
  • Range : -20 °C to 60 °C
  • Accuracy : < ± 1 °C
  • Resolution : 0.1 °C
External temperature probe
  • Range : 2 canals, -20.0 °C to +800.0 °C
  • Accuracy : < ± 2 °C at 0 °C to 133 °C, otherwise 1.5 % of the value, according to the directive EN 50379-2
  • Resolution : 0.1 °C
Relative humidity
  • Range : 0 % bis 100 % r.H. (relative humidity), non condensing
  • Accuracy : < ± 2 % r.H., at 0 to 90 % r.H., otherwise< 3 % r.H.
  • Resolution : 0.1 % r.H.
Barometric Pressure
  • Range : ± 300 hPa bis 1,100 hPa
  • Accuracy : < ± 1.5 % hPa of reading
  • Resolution : 0.1 hPa
  • Current consumption : 4 AA rechargeable batteries or 4 AA disposable batteries 1.5 volt
  • Interfaces : USB interface for data transfer to a PC. It is possible to transfer the data directly from the meter to the Wöhler TD 600 thermal fast printer.
  • Operating temperature : 5 °C to +40 °C
  • Dimensions : 80 x 225 x 60 mm

เอกสารข้อมูลผลิตภัณฑ์

Download File : woehler DC 410-_technical data