ELECTRICAL SPECIFICATIONS |
Air velocity
Measurement |
Range |
Resolution |
Accuracy |
Air velocity |
m/s |
0.2 to 5.0 m/s |
0.01 m/s |
± (5% + a reading)
± (1% + a full scale) |
5.1 to 25.0 m/s |
0.1 m/s |
km/h |
0.70 to 18.00 km/h |
0.01 Km/h |
18.0 to 72.0 km/h |
0.1 km/h |
Mile/h (MPH) |
0.50 to 11.20 mile/h |
0.01 mile/h |
11.2 to 44.7 mile/h |
0.1 mile/h |
knot |
0.40 to 9.70 knot |
0.01 Knot |
9.7 to 38.8 knot |
0.1 knot |
FPM ( Ft/min) |
40 to 3940 ft/min |
1 ft/min |
Air temperature
Measurement |
Range |
Resolution |
Accuracy |
Air temperature |
0 to 50℃ |
0.1℃ |
±0.8℃ |
Thermocouple probe. Type K/ Type J
Measurement |
Range |
Resolution |
Accuracy |
Thermometer (Type K) |
-50.0 to 1300.0℃ |
0.1 ℃ |
±(0.4 % + 0.5℃) |
-50.1 to -100.0℃ |
±(0.4 % + 1℃) |
Thermometer (Type J) |
-50.0 to 1200.0℃ |
0.1 ℃ |
±(0.4 % + 0.5℃) |
-50.1 to -100.0℃ |
±(0.4 % + 1℃) |
Display |
LCD size : 52 mm x 38 mm
LCD with green backlight (ON/ OFF) |
Air velocity |
m/S |
Meters per second |
Km/h |
Kilometers per hour |
Ft/min |
FPM, feet per minute |
Mile/h |
mph, miles per hour |
Knot |
Nautical miles per hour |
Air flow |
CMM |
Cube meters per minute |
CFM |
Cube feet per minute |
Temp. unit |
Type K/ Type J thermometer (℃/ ℉)
Air temperature (℃/ ℉) |
Circuit |
Custom one-chip of microprocessor LSI circuit. |
Datalogger Sampling Time
Setting range |
Auto |
1 second to 3600 seconds
(Sampling time can set to 1 second, but memory data may loss) |
Manual |
Push the data logger button once will save data one time
(Set the sampling time to 0 second.)
(Manual mode, can also select the 1 to 99 position ( Location ) no.) |
Memory Card |
SD memory card. 1 GB to 16 GB. |
Advanced |
- Set clock time (Year/ Month/ Date/ Hour/ Minute/ Second)
- Set sampling time
- Auto power OFF management
- Set beep Sound ON/OFF
- Decimal point of SD card setting
- SD memory card Format
- Set thermometer type to Type K or Type J
- Set temperature unit to or ℃ ℉
- Set air flow type (CFM/USA, CMM/EURO)
- Set air flow area dimension
|
Temperature Compensation |
Automatic temp. compensation for the Anemometer function and the type K/J thermometer |
Data Output |
RS232/USB PC computer interface
- Connect the optional RS232 cable UPCB-02 will get the RS232 plug
- Connect the optional USB cable USB-01 will get the USB plug.
|
Data Hold |
Freeze the display reading. |
Memory Recall |
Maximum & Minimum value |
Sampling Time of Display |
Approx. 1 second. |
Power Supply |
Battery AA × 6 or Adapter ADC 9V (optional) |
Dimension (Weight) |
- Main Unit: 203 x 76 x 38 mm (515 g)
- Anemometer sensor head Round: ø72mm
|