HIOKI PQ3100-92 Power Quality Analyzer Kit

Code: PQ3100-92

Power Quality Analyzer Kit 3-Phase 4-Wire Power Quality Analyzer, Standards 1000VAC (CATIII), 600VAC (CAT IV), DC/ 50 Hz/ 60 Hz

Description

HIOKI PQ3100-92 Power Quality Analyzer Kit

Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PQ3100 is a comprehensive but easy-to-use power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues.

Key Features
  • Record data including voltage, current, power, harmonics, and flicker simultaneously along a single time axis
  • Measure up to 6000 A AC
  • Capture all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data
  • Quick Set: Easy-to-understand on-screen guide for measurement procedures
  • Bundled PQ ONE application software makes it easy to create reports
  • Record waveforms for up to 1 second before and 10 seconds after an anomaly occurs
  • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor)
  • Directly supply power to connected current sensors
  • Send measured values to HIOKI data loggers using a Bluetooth® wireless technology compatible adapter (LR8410 Link-compatible products), Ver. 2.0 and later

Standard equipment

  • POWER QUALITY ANALYZER PQ3100* : 1
  • AC CURRENT SENSOR CT7136 : 4
  • CARRYING CASE C1009 : 1
  • SD MEMORY CARD 2GB Z4001 : 1

SPECIFICATION 
AC/DC Yes
Fundamental frequency DC/ 50 Hz/ 60 Hz
Measurement lines
  • Single-phase 2-wire
  • single-phase 3-wire
  • three-phase 3-wire
  • three-phase 4-wire + Ch. 4
Voltage ranges 1000.0 V rms or DC, Transient measurement 2.200 kV peak
Current ranges
  • 50.000 mA AC to 5.0000 kA AC
  • 10.000 A DC to 2.0000 kA DC

(depends on current sensor in use)

Power ranges 50.000 W to 6.0000 MW
(determined automatically based on current range in use)
Basic accuracy Voltage: ±0.2% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy
AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Voltage input Number of channels 4 (U4: Not isolated)
Maximum terminal-toground rated voltage 1000 V (measurement category III)
600 V (measurement category IV)
Current input Number of channels 4
Power supply for sensors Yes
Measurement parameters Voltage
  • 1/2 RMS value (half-wave offset wave calculation)
  • RMS value
  • waveform peak
  • Voltage DC
  • Unbalance factor (negative-phase, zero-phase)
  • frequency (1 wave/ 200 ms/ 10 sec.)
Crest factor
Current
  • Inrush current (half-wave)
  • RMS value
  • waveform peak
  • Current DC
  • Unbalance factor (negative-phase, zero-phase)
  • K factor
1/2 RMS value (half-wave offset wave calculation), crest factor
Power
  • Active power
  • Reactive power
  • Apparent power
  • Power factor,
  • Displacement power factor
  • Active energy
  • Reactive energy
Apparent energy, Electrical charges
Flicker Pst, Plt, ΔV10 (3 channels simultaneously)
Harmonics
  • 0th order (DC) to 50th order
  • Voltage/ Current/ Power
  • Phase angle (voltage/ current)
  • Voltage/Current phase difference
  • Total harmonic distortion ratio (voltage/ current)
Inter-harmonics 0.5 th order to 49.5 th order, voltage/ current
High-order harmonics n/a
Time-series measuremen Recording period Max. 1 year
Recording interval time 200 ms/600 ms/150 cycles (with 50 Hz input)/1/2/5/10/15/30 sec. to 2 h
Event measurement Event statistical processing Displays the number of occurrences by event per day
Waveform acquisition: Before event Max. 1 sec.
At event 200 ms
After event Max. 10 sec.
Event parameters Measurable event parameters Voltage Swell/ Dip/ Interruption/ Frequency fluctuations/ Inrush current/ THD
Transient voltage 200 kS/s, 2.2 kV
Setting aid Quick Set
Operating temperature and humidity -20 to 50°C / 80%RH
IEC 61000-4-30 standard compliance Class S
Protection Class IP54 (EN60529) with connection cable connected, but not including cable tip
Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A),
Battery pack Z1003 (Continuous use: 8 hr Charging time: Max. 5 hr 30 m with AC adapter)
Interfaces
  • SD/SDHC memory card
  • RS-232C (for communication/ LR8410 link (Ver. up)
  • LAN (HTTP server/ FTP (Ver. up)/ Send e-mail (Ver. up)
  • USB 2.0 (for communication)
Dimension/ Weight 300 x 211 x 68 mm / 2.5 kg
Accessories Standard

  • Instruction manual ×1
  • Measurement guide ×1
  • Voltage cord L1000-05 ×1 set
    (Red/Yellow/Blue/Gray/Black, Alligator clip ×5, Spiral tube ×5)
  • Color clip (for identifying clamp sensor color) ×1 set
  • Spiral tube ×5
  • AC adapter Z1002 ×1
  • Strap ×1
  • USB cable (1 m 3.28 ft length) ×1
  • Battery pack Z1003 ×1
  • PQ ONE (software, CD)
Kit includes PQ3100-92
  • AC CURRENT SENSOR (CT7136) x 4
  • CARRYING CASE (C1009) x 1
  • SD MEMORY CARD 2GB (Z4001) x 1

เอกสารข้อมูลผลิตภัณฑ์

Download File : PQ3100