WÖHLER A 450 Flue Gas Analyzer 10,000 PPM (Standard set)

Code: 5181

Flue Gas Analyzer 10,000 PPM CO Measurement of O2, COV, NOx from chimneys in various industries, Measuring range CO0 to 10,000 ppm

Description

Flue Gas Analyzer  10,000 PPM (Standard set)

This is where Wöhler excels: A reasonably priced flue gas analyzer that offers all measurement and tuning functions. A small and lightweight flue gas analyzer enclosed in an eye-catching, sturdy housing. The Wöhler A 450 is a handheld device with user friendly touchscreen control, displays all measurement data on screen or connect and view on your smart devices.

Wöhler, Germany

Feature

  • Open the meter immediately
  • Durable and compact measuring instrument for measurement and built-in adjustment function
  • 5-inch color touch screen, showing 14 values on one page
  • Wireless network connection
  • Wöhler A 450 app for both Android and iOS

More information

  • Wöhler A 450 with 10.000 ppm CO sensor (not H2 compensated)
  • WIFI, USB and IR interface
  • probe 250 mm with 1.5 m hose
  • USB charger with micro USB cable
  • LI-ION battery 3,6 V / 6700 mAh
  • 25 cotton filters
  • Plastic case
  • cone Ø 8 mm

    5″ large color touchscreen
    All measured values available at a glance thanks to high-resolution display

    Interface to the printer
    Printout of the measured data on site

    Wöhler A 450 App
    Displaying the measured data on a mobile device

    Easy maintenance
    Condensate trap can easily be pulled out to change cotton wool and water stop fi lters.

    All values at a glance
    The tuning guide offers an advanced guidance to the technician to properly adjust the burner

    Perfect size
    Compact and light in a plastic case

 

General Information
  • Power supply : Lithium-Ion, rechargeable battery 3.7 V, 2,250 mAh, ชาร์จผ่าน USB
  • Operation time is about 17 hours (depending on usage status).
  • Charging time is about 7 hours.
  • Storage temperature -20 to 50 ° C
  • Operating Temperature 5 to 40 ° C
  • Weight 620 g (without sensor)
  • 160 x 110 x 45 mm (excluding probe)
  • 1.5 m long probe
Technical Information
 

Oxygen concentration (O2)

  • Range 0.0 - 21.0 %
  • Accuracy ±0.3 %

 

Carbon monoxide (COV 10,000 ppm), not H2 compensated

  • Range 0 - 10,000 ppm
  • Resolution 1 ppm
  • Accuracy ±10 f.m., absolute ±40 ppm
Nitric oxide concentration (NOV)

  • Range 0 - 3,000 ppm
  • Resolution 1 ppm
  • Accuracy ±5 ppm (< 100 ppm), otherwise 5 % of reading
Chimney draught / differential pressure (PD)

  • Range 0.00 ± 110.00 hPa
  • Resolution 1 Pa
  • Accuracy 2 Pa (< 40 Pa), otherwise 5 % of reading
Flue gas temperature (TS)

  • Range -20.0 to 800 °C
  • Resolution 0.1 °C
  • Accuracy 0 - 133 °C : ±2 °C , 133 - 800 °C : ±1.5 % of reading
Combustion air temperature (TA)

  • Range -20.0 to 100 °C
  • Resolution 0.1 °C
  • Accuracy ±1 °C
  • Battery operating time approx. 17 h

เอกสารข้อมูลผลิตภัณฑ์

Download File : Woehler A450

เอกสารคู่มือ

Download File : Wohler A450/A450 L Flue Gas Analyzer Operation Manual