WÖHLER A450 L Flue Gas Analyzer 100,000 PPM

Code: 4672

Flue Gas Analyzer 100,000 PPM CO Measurement of O2, COV, NOx from chimneys in various industries, Measuring range CO0 to 100,000 ppm

Description

Flue Gas Analyzer 100,000 PPM

A reasonably priced flue gas analyzer that offers all measurement and tuning functions. A small and lightweight flue gas analyzer enclosed in an eye-catching, sturdy housing. The Wöhler A 450 is a handheld device with user friendly touchscreen control, displays all measurement data on screen or connect and view on your smart devices.

Wöhler, Germany

Feature

  • Open the meter immediately
  • Durable and compact measuring instrument for measurement and built-in adjustment function
  • 5-inch color touch screen, showing 14 values on one page
  • Wireless network connection
  • Wohler A 450 app for both Android and iOS

More information

  • Wöhler A 450 L
  • 100,000 ppm CO-Sensor
  • WLAN-, USB- and IR interface
  • probe 250 mm with 1.5 m hose
  • USB charger with micro USB cable
  • Li-Ion battery 3.6 V / 2250 mAh
  • 25 cotton filters
  • Plastic case
  • cone Ø 8 mm

5″ large color touchscreen
All measured values available at a glance thanks to high-resolution display

Interface to the printer
Printout of the measured data on site

Wöhler A 450 App
Displaying the measured data on a mobile device

Easy maintenance
Condensate trap can easily be pulled out to change cotton wool and water stop fi lters.

All values at a glance
The tuning guide offers an advanced guidance to the technician to properly adjust the burner

Perfect size
Compact and light in a plastic case

General Information
  • Power supply : Lithium-Ion, rechargeable battery 3.7 V, 2,250 mAh, ชาร์จผ่าน USB
  • Operation time is about 17 hours (depending on usage status).
  • Charging time is about 7 hours.
  • Storage temperature -20 to 50 ° C
  • Operating Temperature 5 to 40 ° C
  • Weight 620 g (without sensor)
  • 160 x 110 x 45 mm (excluding probe)
  • 1.5 m long probe
Technical Information
Oxygen concentration (O2) in flue gas
  • Display : Volume % referenced to dry flue gas
  • Measurement principle : Electrochemical sensor
  • Range 0.0 to 21.0 Vol. %
  • Accuracy ±0.3 Vol. %
Flue gas temperature (TS)
  • Display : °C
  • Measurement principle : Thermocouple (NiCr-Ni)
  • Range : -20.0 to 800 °C
  • Resolution 0.1 °C
  • Accuracy 0 to 133 °C: ±2°C
    and 133 to 800 °C: ±1.5 % of reading
Carbon monoxide (COV5,000 ppm) in flue gas
  • Display : Volume ppm referenced to dry flue gas
  • Measurement principle : Electrochemical sensor, not H2
    compensated
  • Range 0 to 100,000 Vol. ppm
  • Resolution 1 Vol. ppm
  • Accuracy ±100 ppm (< 1,000 ppm), 10 % f.m.
Combustion air temperature (TA)
  • Display : °C
  • Measurement principle : Thermocouple (NiCr-Ni)
  • Range -20.0 to 100 °C
  • Resolution 0.1 °C
  • Accuracy ±1°C
ออกไซด์ของไนโตรเจน (NOx) ในแก๊สจากปล่องควัน (optional)
  • หน่วยการวัดเป็น ppm
  • หลักการวัดแบบ Electrochemical sensor
  • ช่วงของการวัด 0 ถึง 3,000 ppm
  • ค่าความละเอียด 1 ppm
  • ค่าความถูกต้อง ±5 (< 100 ppm), และ 5 % ของการอ่าน
Chimney draught / differential pressure (PD)
  • Display : Pascal
  • Measurement principle : Semi-conductor diaphragm
  • Range 0.00 to ±110.00 hPa
  • Resolution 1 Pa
  • Accuracy 2 Pa (< 40 Pa), otherwise 5 % of reading

 